SOMMER CABLE (N)YM-(ST)-J 3x4 terminated IEC and SCHUKO
Custom Terminated Shielded Power Cable with Schuko and IEC Gold | Solid OFC Copper | Section: 3x4mmq
Se effettui un ordine superiore a € 300 con due o più prodotti, la spedizione sarà gratuita. Le tempistiche stimate di spedizione sono indicate.
Paga in modo semplice e sicuro con Carta di credito, Contrassegno, AMEX, PayPal e Bonifico bancario. La tua privacy è garantita da connessioni sicure.
Tutti i prodotti sono coperti da Garanzia convenzionale di 2 anni. Risolviamo problemi di qualsiasi natura con professionalità e correttezza.
Solo tramite eMail dal Lunedì al Venerdì dalle ore 9:30 alle 15:00.
OFC Copper Power Cable with 3 solid core x 4mmq conductors terminated by hand with gold-plated connectors. External dimensions: 11.8mm. Shielding: AL / PT foil + tinned drain wire.
Caution: With solid copper conductors, the cable is very rigid
Available lengths selectable from drop-down menu.
You can rely on the shielding of the NYM...
Because it protects not only against rain, but with this cable also against electromagnetic interference fields. This is important in hospitals, server and computer areas and in any demanding studio, as well as in any radiation-sensitive living area. The shielded {NAME cable with protective conductor is suitable for all indoor and outdoor installations (above, inside and under plaster) as long as they are not exposed to direct sunlight. The wires are colour coded according to VDE 0293 and twisted in layers with a tinned 1.5 mm² drain wire. The wires comply with the EC Low Voltage Directive EWG93/68/ or EWG73/23.
ADVANTAGES
- EMC shielding against electromagnetic interference signals
- Complies with VDE 0250, VDE 0482-332-1-2 / IEC 60332-1 and other requirements
- Mobile application up to +5°C
APPLICATIONS
- For all installations, especially in sensitive locations such as hospitals, server rooms, studios
- For surface and flush mounting, as well as in humid environments
CONNECTORS
- Material: oxygen-free OFC copper
- Properties: analogue
- Area of application: installation
- Application area: ELA 100 V
- Application: power cable
- Colour: grey
- Construction: (N)YM-(ST)-J
- Sheath material: PVC, flame retardant
- Sheath material (power) PVC, flame retardant and self-extinguishing
- Sheathing Ø: 11.80 mm
- Number of Channels (power): 1
- Inner conductor (power): 3
- Inner conductor (power): 4.00 mm²
- Inner conductor Ø (power): 2.26 mm
- AWG (power): 11
- Shielding: AL / PT foil + tinned drain wire
- Copper stranding (power): 1
- Copper stranded wire Ø (power): 1.78 mm
- Conductor insulation material: PVC
- Weight per 1 m: 300 g
- Style variant: round
- Min. temperature: -40 °C
- Max. temperature: 70 °C
- Width: 11.8 mm
- Height: 11.8 mm
- Insulation resistance. per 1 km: 0.02 GΩ
- Insulation resistance. per 1km (power): 0.02 GΩ
- Test voltage: 2000 V
- Rated voltage (power): 500 V
- Operating voltage (power): 350 V
- Old article number: 720-0051-03040
- BPVo-Euroclass: Fca